01
7 Jan 2019
Hyang Oil and Gas specializes in producing all kinds of drilling field camps, generator houses, Dog houses, gatehouse, logging unit, Laboratory room, material houses, and worker living camp and office camp ect.
According to the different operation conditions, the barracks are divided into different grades, the barracks in the operation area, most of them are explosion-proof barracks, in order to ensure the safety of personnel in the operation area when an accident occurs, there are positive pressure explosion-proof camp.

01
7 Jan 2019
Camp manufacturing is usually divided into the main body and the auxiliary two parts, similar to a simple movable house. The camp is Steel structure house depending on the place of use, the equipment is different, can be used as working office, living room, kitchen, toilet, canteen.
The camp Interior decoration materials and furniture use green health and environmental protection products. The outside door of the staff working or resting room has an escape function and a separate fire escape safety door is set up. Equipped with escape lock. Each room should be equipped with reliable smoke alarms, emergency lights and fire extinguishers and fixtures.

01
7 Jan 2019
The insulation material of the feild camp body is filled with rock wool (fire grade B2 or above)
Top foam thickness is not less than 50mm, wall filling thickness is not less than 100mm, floor filling is not less than 100mm. The filling thickness of the camp partition wall is not less than 50mm, and all the gaps are filled with polyurethane foam. The escape door should also consider insulation. Indoor equipment: Grading takes into account the original and temporary fixing of objects in the feild camp. To ensure that the relocation of the camp does not damage the equipments and the facilities in the camp.

01
7 Jan 2019
Lifting: base with lifting bar (through type lifting bar, set drop shaped lifting point, lifting point baffle is round. It should be greater than 1.5 times the rope diameter of the sling, and the hoisting direction and horizontal direction are 45°), which can meet the bottom of the camp
Part lifting, the roof design rope limit device, strength to meet the lower lifting, design safety factor >3.
The whole material is waterproof and flame retardant.
The decorative layer in the interior of the room is completely insulated from the steel outer layer and the skeleton, and is nothing more than insulation of the current channel.
The water supply and drainage facilities and bathroom supplies are closely linked and reasonable, and can withstand 0.6MPa test without leakage.
Meet the requirements of high temperature exposure catalysis and wind sand in desert areas.
Indoor furniture is not cracked or deformed under humid weather conditions.